9
(total 15872 records) with date and time stamp, extensive Diagnostic events log
and register, and feature a password protected access to the process parameters
to ensure against tampering or resetting.
(* - optional feature)
4.2 Specifications
Fluid Types:
Steam, Gas, Liquid.
Flow Accuracy (Including Linearity):
±1% of AR.
Repeatability:
±0.25% of full scale.
Ambient Temperature:
-12 °C to 65 °C (-15 °F to 149 °F).
Fluid Temperature:
-20 °C to 232 °C std./to 260 °C opt.
(-3 °F to 450 °F std./to 500 °F opt).
Fluid Temperature Measurement Range*:
-20 to 260C (-4 to 500 °F).
Temperature Accuracy (Including Linearity)*:
+/- 0.5C
Fluid Pressure Measurement Range*:
can be ordered for following options: 0 - 100 PSIA
0 - 200 PSIA
0 - 300 PSIA
0 - 500 PSIA
0 - 750 PSIA
0 - 1000 PSIA
Pressure Accuracy (Including linearity)*
: +/- 0.5% of full scale.
Fluid Proof Pressure*:
3 X F.S.
Fluid Burst Pressure*:
10 X F.S.
Flow Response Time:
Adjustable based on Noise Redaction Filter (NRF) and
Damping settings (minimum 1000 ms).
Analog Output Signals:
Linear 4-20 mA, self-powered (sourcing type,
non-isolated), 600 ohms maximum loop resistance.
Optically Isolated Outputs:
UCE @ 40Vdc, ICE @ 150 mA (Voltage –
Isolation: 5000 Vrms).
Comentários a estes Manuais